ECA Proteus fault E05

Fan feedback fault

Gas boiler
Free account: the readings and the manual page (page 27). No card needed.See the full E05 answer

What it means

Fan modulation feedback fault, typically caused by disconnected or loose fan cable connectors, or a faulty fan or main board.

Likely causes

  1. Fan modulation cable connector not mounted or loose contact
  2. Faulty fan
  3. Faulty main board

Where to start

  1. Check related cables at the fan and circuit board side for mounting/loose contact. If YES (problem found), replace the fan cables; if NO (cables OK), replace the fan.
  2. If replacing fan does not resolve issue (YES further fault), replace the main board.