ECA Proteus fault F51
PT1000 solar sensor fault
Gas boilerFree account: 2 more checks and the manual page (page 40). No card needed.See the full F51 answer
What it means
Fault relating to the PT1000 solar sensor. Requires confirming correct parameter setting for model type (P00=1 for HM model; P00: 2,4 used for HST model) before checking sensor wiring and resistance.
Likely causes
- Incorrect P00 parameter setting for model type
- PT1000 sensor cables not mounted
- Loose contact on sensor cable
- Damaged sensor cable
- Faulty PT1000 sensor
- Faulty main board
Where to start
- Ensure that P00=1 for HM model (P00: 2,4 is used for HST model)
- Check the PT1000 sensor cables for mounting and loose contact
- If cables are fine, check PT1000 sensor for any problem via resistance check
The full answer, free
- 2 more checks in order
- How to put it right, step by step
- The manual page for this fault (page 40), right under the answer
Safety: Isolate gas and power before you open the case. If you have been into the gas side, do a tightness test, and a combustion and flue check before you hand back. Gas Safe (UK) or RGI (Ireland) work only.
Full F51 fix, readings and manual page. Free.See the full answer
From the ECA manual for the Proteus. Check the model on the data plate before you order parts.
Other ECA Proteus fault codes
- E01Ignition/ionization electrode fault
- E02Relevant to main board and gas valve faults
- E033 way shaft group / motorized valve related fault
- E05Fan feedback fault
- E08Relevant to main board and gas valve faults
- E09No feedback from gas valve
- E12Relevant to main board and gas valve faults
- E15Temperature sensors measurement deviation fault
- E16Related to plate heat exchanger / pump fault
- E17Related to plate heat exchanger / pump fault
- E18Immersion/flue gas NTC related fault
- E21Relevant to main board and gas valve faults
- E33Return water temperature sensor fault
- E35Supply water temperature sensor fault
- E82Ignition/ionization electrode fault
- F073 way shaft group / motorized valve related fault
- F13Over-resetting fault
- F25Relevant to main board fault
- F39Outdoor sensor fault
- F47Water pressure sensor fault
- F50Storage tank sensor fault
- F52Immersion type NTC fault
- F53Flue gas sensor fault
- F58Relevant to main heat exchanger fault