ECA Proteus fault E18
Immersion/flue gas NTC related fault
Gas boilerFree account: 7 more checks, the readings and the manual page (page 62). No card needed.See the full E18 answer
What it means
Associated error code relevant to the Immersion Type NTC sensor (tap water temperature sensor) and also listed as relevant for Flue Gas Sensor faults. Indicates sensor circuit issue affecting boiler operation.
Likely causes
- Temperature change on temperature sensor too much (>30°C)
- Temperature sensor cables not working properly
- CH return water temperature sensor fault
- CH supply water temperature sensor fault
- Main board may be broken
- Faulty immersion type NTC sensor
- Damaged cable connections to the NTC sensor
- Rusting, corrosion, or deformation on the immersion probe
- Faulty flue gas sensor
- Damaged cable connections to the flue gas sensor
Where to start
- Check whether the temperature sensor cables are working properly. If YES (cables show the fault condition), replace the cables in case of any problem; if NO (cables are not the cause), check/replace CH return water temperature sensor.
- If replacing CH return water temperature sensor does not resolve (NO), check/replace CH supply water temperature sensor.
- If replacing CH supply water temperature sensor does not resolve (NO), replace main board.
The full answer, free
- 7 more checks in order
- The readings and component tests from the manual
- How to put it right, step by step
- The manual page for this fault (page 62), right under the answer
Safety: Isolate gas and power before you open the case. If you have been into the gas side, do a tightness test, and a combustion and flue check before you hand back. Gas Safe (UK) or RGI (Ireland) work only.
Full E18 fix, readings and manual page. Free.See the full answer
From the ECA manual for the Proteus. Check the model on the data plate before you order parts.
Other ECA Proteus fault codes
- E01Ignition/ionization electrode fault
- E02Relevant to main board and gas valve faults
- E033 way shaft group / motorized valve related fault
- E05Fan feedback fault
- E08Relevant to main board and gas valve faults
- E09No feedback from gas valve
- E12Relevant to main board and gas valve faults
- E15Temperature sensors measurement deviation fault
- E16Related to plate heat exchanger / pump fault
- E17Related to plate heat exchanger / pump fault
- E21Relevant to main board and gas valve faults
- E33Return water temperature sensor fault
- E35Supply water temperature sensor fault
- E82Ignition/ionization electrode fault
- F073 way shaft group / motorized valve related fault
- F13Over-resetting fault
- F25Relevant to main board fault
- F39Outdoor sensor fault
- F47Water pressure sensor fault
- F50Storage tank sensor fault
- F51PT1000 solar sensor fault
- F52Immersion type NTC fault
- F53Flue gas sensor fault
- F58Relevant to main heat exchanger fault