ECA Proteus fault F53

Flue gas sensor fault

Gas boiler
Free account: 7 more checks, the readings and the manual page (page 62). No card needed.See the full F53 answer

What it means

Error code relevant to the Flue Gas Sensor protecting the boiler against overheating. Malfunction can cause the boiler to burn without overheating protection or stop functioning entirely.

Likely causes

  1. Flue gas temperature sensor cables not mounted
  2. Loose contact on sensor cable
  3. Damaged sensor cable
  4. Faulty flue gas temperature sensor
  5. Faulty main board
  6. Damaged cable connections
  7. Rusting, corrosion, or deformation on the sensor probe

Where to start

  1. Check the flue gas temperature sensor cables for mounting and loose contact
  2. If cables are fine, check flue gas temperature sensor for any problem via resistance check
  3. If sensor resistance is faulty, replace sensor