ECA Proteus fault E82
Ignition/ionization electrode fault
Gas boilerFree account: 11 more checks, the readings and the manual page (page 66). No card needed.See the full E82 answer
What it means
Primary relevant error code associated with faulty ignition or ionization electrode, affecting gas-air mixture ignition and flame detection in the burner.
Likely causes
- Burrs, dirt or debris at inlet/outlet ends or inside venturi
- Improper installation with gas pipe, fan, or silencer
- Improper burning emission values
- Noisy (whistling) operation
- Gas valve failure causing improper gas regulation or no burn
- No ignition and burning as result of electrode end distance too much or too narrow
- Noisy burning (explosion burning) as result of late ignition
- Due to electrode being away from the burner, reduced ionization flow and flame loss in boiler time to time
Where to start
- Visual inspection: check for burrs, dirt, etc. at inlet and outlet ends and inside venturi
- Check installation of venturi with gas pipe, fan, and silencer
- Check burning emission values using a gas analysis boiler
The full answer, free
- 11 more checks in order
- The readings and component tests from the manual
- How to put it right, step by step
- The manual page for this fault (page 66), right under the answer
Safety: Isolate gas and power before you open the case. If you have been into the gas side, do a tightness test, and a combustion and flue check before you hand back. Gas Safe (UK) or RGI (Ireland) work only.
Full E82 fix, readings and manual page. Free.See the full answer
From the ECA manual for the Proteus. Check the model on the data plate before you order parts.
Other ECA Proteus fault codes
- E01Ignition/ionization electrode fault
- E02Relevant to main board and gas valve faults
- E033 way shaft group / motorized valve related fault
- E05Fan feedback fault
- E08Relevant to main board and gas valve faults
- E09No feedback from gas valve
- E12Relevant to main board and gas valve faults
- E15Temperature sensors measurement deviation fault
- E16Related to plate heat exchanger / pump fault
- E17Related to plate heat exchanger / pump fault
- E18Immersion/flue gas NTC related fault
- E21Relevant to main board and gas valve faults
- E33Return water temperature sensor fault
- E35Supply water temperature sensor fault
- F073 way shaft group / motorized valve related fault
- F13Over-resetting fault
- F25Relevant to main board fault
- F39Outdoor sensor fault
- F47Water pressure sensor fault
- F50Storage tank sensor fault
- F51PT1000 solar sensor fault
- F52Immersion type NTC fault
- F53Flue gas sensor fault
- F58Relevant to main heat exchanger fault