Worcester Bosch Greenstar 8000 fault 2949

No flame signal with high output

Gas boiler
Free account: 2 more checks, the readings and the manual page (page 78). No card needed.See the full 2949 answer

What it means

Blocking fault (category B): no flame signal at high output, which can be caused by strong winds or flue gas recirculation. The burner restarts automatically after purging.

Likely causes

  1. Strong winds.
  2. Flue gas recirculation.
  3. Incorrect flue terminal position.
  4. Incorrect CO2 settings.
  5. Damaged burner or heat exchanger gaskets.
  6. Damaged inner flue gaskets.
  7. Gas pressure dropping low at full load.

Where to start

  1. Check the flue integrity.
  2. Check the flue terminal position.
  3. Check the CO2 settings and adjust.

The full answer, free

  • 2 more checks in order
  • The readings and component tests from the manual
  • How to put it right, step by step
  • The manual page for this fault (page 78), right under the answer

Safety: Isolate gas and power before you open the case. If you have been into the gas side, do a tightness test, and a combustion and flue check before you hand back. Gas Safe (UK) or RGI (Ireland) work only.

Full 2949 fix, readings and manual page. Free.See the full answer

From the Worcester Bosch manual for the Greenstar 8000. Check the model on the data plate before you order parts.

Other Worcester Bosch Greenstar 8000 fault codes