Worcester Bosch Greenstar 8000 fault 2962

No fan signal available

Gas boiler
Free account: the readings and the manual page (page 78). No card needed.See the full 2962 answer

What it means

Locking fault (category V): the control has no signal back from the fan. The manual groups 2961 and 2962 in one entry.

Likely causes

  1. Loss of mains voltage to the fan.
  2. Fan harness fault.
  3. PWM signal fault.
  4. Faulty fan.
  5. Faulty PCB.

Where to start

  1. Check the mains voltage to the fan.
  2. Check the fan harness for continuity and replace if required.
  3. Check the pulse width modulation (PWM) signal.

The full answer, free

  • The readings and component tests from the manual
  • How to put it right, step by step
  • The manual page for this fault (page 78), right under the answer

Safety: Isolate gas and power before you open the case. If you have been into the gas side, do a tightness test, and a combustion and flue check before you hand back. Gas Safe (UK) or RGI (Ireland) work only.

Full 2962 fix, readings and manual page. Free.See the full answer

From the Worcester Bosch manual for the Greenstar 8000. Check the model on the data plate before you order parts.

Other Worcester Bosch Greenstar 8000 fault codes