Worcester Bosch Greenstar 8000 fault 2970

Pressure drop in heating system too rapid

Gas boiler
Free account: the readings and the manual page (page 79). No card needed.See the full 2970 answer

What it means

Blocking fault (category B): too many unexpected pressure drops in a short time.

Likely causes

  1. System pressurised with the intelligent filling loop active and then vented.
  2. System leak.

Where to start

  1. Check whether the code appeared after the system was pressurised, the intelligent filling loop activated and the system then vented.
  2. Switch off the intelligent fill in the system menu, re-pressurise manually and vent the system.
  3. Make sure the pressure is correct.

The full answer, free

  • The readings and component tests from the manual
  • How to put it right, step by step
  • The manual page for this fault (page 79), right under the answer

Safety: Isolate gas and power before you open the case. If you have been into the gas side, do a tightness test, and a combustion and flue check before you hand back. Gas Safe (UK) or RGI (Ireland) work only.

Full 2970 fix, readings and manual page. Free.See the full answer

From the Worcester Bosch manual for the Greenstar 8000. Check the model on the data plate before you order parts.

Other Worcester Bosch Greenstar 8000 fault codes