ECA Proteus fault F81

Temperature sensor deviation test waiting

Gas boiler
Free account: 3 more checks, the readings and the manual page (page 42). No card needed.See the full F81 answer

What it means

Indicates a deviation test condition for the supply/return or DHW temperature sensors, requiring a power cycle wait period before further diagnosis.

Likely causes

  1. Temporary sensor deviation detected requiring verification
  2. Supply/return or DHW temperature sensor cables not mounted
  3. Loose contact on sensor cables
  4. Damaged sensor cables
  5. Faulty temperature sensors
  6. Faulty main board

Where to start

  1. Turn off electricity and wait 5 minutes
  2. Turn on electricity and check if the fault has disappeared
  3. If fault persists, check supply/return or DHW temperature sensor cables for mounting and loose contact

The full answer, free

  • 3 more checks in order
  • The readings and component tests from the manual
  • How to put it right, step by step
  • The manual page for this fault (page 42), right under the answer

Safety: Isolate gas and power before you open the case. If you have been into the gas side, do a tightness test, and a combustion and flue check before you hand back. Gas Safe (UK) or RGI (Ireland) work only.

Full F81 fix, readings and manual page. Free.See the full answer

From the ECA manual for the Proteus. Check the model on the data plate before you order parts.