Ideal Logic Air fault 370-F24

Circulation pump error

Heat pump

What it means

Heat Pump fault F24: circulation pump error.

Likely causes

  1. Circulation pump failure
  2. Pump blocked or seized
  3. Wiring fault to pump
  4. Frost accumulation on evaporator due to outdoor humidity/temperature conditions
  5. Electrical interference from inadequate cable separation
  6. Water ingress from improperly routed cables or loose cable glands
  7. Dwelling room temperature dropped to ≤8°C
  8. Inadequate corrosion inhibitor dosing leading to gradual system performance deterioration
  9. Missing or undersized system filter allowing debris into primary circuit
  10. Dwelling ambient temperature at or below 8°C
  11. Ambient air temperature at or below 1°C
  12. Refrigerant leak from circuit

Where to start

  1. Read Primary flow temp, Hot water temp, Outside temp, Primary water flow, Compressor %, CH1 Pump, CH2 Pump, Diverter valve, Immersion heater status directly from home screen to verify system operation
  2. Identify 'Alarm' symbol to indicate a plant error
  3. Identify 'Maintenance/Special operations' symbol for maintenance message or special operation feedback

The full answer, free

  • 75 more checks in order
  • The readings and component tests from the manual
  • How to put it right, step by step
  • The manual page for this fault (page 103), right under the answer

Safety: Isolate the outdoor unit and any backup heater, and give the inverter capacitors time to discharge before you open the electrics. Anything on the refrigerant circuit needs F-gas certification.

From the Ideal manual for the Logic Air. Check the model on the data plate before you order parts.

Other Ideal Logic Air fault codes