Ideal Logic Air fault 9.1.14

2 clock time masters (controller code 100)

Heat pump
Free account: 1 more check, the readings and the manual page (page 74). No card needed.See the full 9.1.14 answer

What it means

Two devices are acting as clock time master, normally because heat pump 2 in a cascade is not set as Slave. Manual chart 9.1.14 (page 74); code 100 on the controller fault list.

Likely causes

  1. Heat pump 2 not configured as Slave.
  2. Faulty indoor unit AVS74 on heat pump 2.
  3. Faulty indoor unit RVS21 on heat pump 2.

Where to start

  1. Read the fault history to confirm the code and when it occurred: Settings, user level Installer (password), Test function menu, Fault History (6800 History 1, 6801 Fault Code 1), page
  2. The last 10 faults can be scrolled through.
  3. Reconfigure heat pump 2 as Slave and check if the fault persists.

The full answer, free

  • 1 more check in order
  • The readings and component tests from the manual
  • How to put it right, step by step
  • The manual page for this fault (page 74), right under the answer

Safety: Isolate the heat pump and any backup heater, and give any inverter capacitors time to discharge before you open the electrics. Anything on the refrigerant circuit needs F-gas certification.

Full 9.1.14 fix, readings and manual page. Free.See the full answer

From the Ideal manual for the Logic Air. Check the model on the data plate before you order parts.