Ideal Logic Air fault 9.1.12

BSB short circuit fault

Heat pump

What it means

A short circuit has been detected on the BSB (Boiler System Bus) communication line, potentially involving diagnostics unit, smart interface, or user interface wiring.

Likely causes

  1. Short in wiring from diagnostics connection to diagnostics unit
  2. Short in wiring from smart interface connection to smart interface
  3. Short in wiring from RVS21 to user interface

Where to start

  1. Check for shorts in wiring from diagnostics connection to diagnostics unit
  2. Check for shorts in wiring from smart interface connection to smart interface
  3. Check for shorts in wiring from RVS21 to user interface

The full answer, free

  • 1 more check in order
  • The readings and component tests from the manual
  • How to put it right, step by step
  • The manual page for this fault (page 73), right under the answer

Safety: Isolate the outdoor unit and any backup heater, and give the inverter capacitors time to discharge before you open the electrics. Anything on the refrigerant circuit needs F-gas certification.

From the Ideal manual for the Logic Air. Check the model on the data plate before you order parts.