Ideal Logic Air fault 9.1.16

Source temperature too low fault

Heat pump

What it means

Fault indicating the heat source temperature (air/refrigerant source) is too low, typically due to airflow restriction in the outdoor unit or pipework blockages.

Likely causes

  1. Blockage in pipework between outdoor and indoor units
  2. Blocked inlet to evaporator
  3. Blocked fan outlet

Where to start

  1. Check for blockage in pipework between outdoor and indoor units
  2. Check if inlet to evaporator is blocked
  3. Check fan outlet for blockages

The full answer, free

  • 12 more checks in order
  • How to put it right, step by step
  • The manual page for this fault (page 74), right under the answer

Safety: Isolate the outdoor unit and any backup heater, and give the inverter capacitors time to discharge before you open the electrics. Anything on the refrigerant circuit needs F-gas certification.

From the Ideal manual for the Logic Air. Check the model on the data plate before you order parts.