Ideal Logic Air fault 127

Anti-legionella temperature fault

Heat pump
Free account: 3 more checks, the readings and the manual page (page 103). No card needed.See the full 127 answer

What it means

The weekly anti-legionella cycle (cylinder to 60°C for 1 hour using the back-up immersion, page 21) did not reach temperature. Manual chart 9.1.18 (page 75); code 127 on the controller fault list.

Likely causes

  1. No 230 Vac at the indoor unit contactor L In connection.
  2. No 230 V at the contactor L Out connection when the back-up heater is switched on.
  3. No 230 Vac at the DHW immersion heater.
  4. DHW immersion heater thermostat not set to maximum.
  5. Faulty DHW immersion heater.

Where to start

  1. Read the fault history to confirm the code and when it occurred: Settings, user level Installer (password), Test function menu, Fault History (6800 History 1, 6801 Fault Code 1), page
  2. The last 10 faults can be scrolled through.
  3. Check for 230 Vac at the indoor unit contactor L In connection.

The full answer, free

  • 3 more checks in order
  • The readings and component tests from the manual
  • How to put it right, step by step
  • The manual page for this fault (page 103), right under the answer

Safety: Isolate the heat pump and any backup heater, and give any inverter capacitors time to discharge before you open the electrics. Anything on the refrigerant circuit needs F-gas certification.

Full 127 fix, readings and manual page. Free.See the full answer

From the Ideal manual for the Logic Air. Check the model on the data plate before you order parts.