Ideal Logic Air fault 9.1.26
No outdoor connection fault
Heat pumpWhat it means
Indoor Unit is unable to establish connection with the outdoor Heat Pump, typically due to wiring issues.
Likely causes
- Wiring from Heat Pump to Indoor Unit not secure
- Wiring from Heat Pump to Indoor Unit connected incorrectly (L to L, N to N, E to E, COM to COM)
- Faulty Indoor Unit Fujitsu PCB
Where to start
- Check wiring from Heat Pump to Indoor Unit is secure
- Check wiring is connected correctly: L to L, N to N, E to E, COM to COM
- If wiring correct and secure, replace Indoor Unit Fujitsu PCB
The full answer, free
- 1 more check in order
- The readings and component tests from the manual
- How to put it right, step by step
- The manual page for this fault (page 77), right under the answer
Safety: Isolate the outdoor unit and any backup heater, and give the inverter capacitors time to discharge before you open the electrics. Anything on the refrigerant circuit needs F-gas certification.
From the Ideal manual for the Logic Air. Check the model on the data plate before you order parts.