Ideal Logic Air fault 9.1.17

7093 DHW setpoint fault (controller code 126)

Heat pump
Free account: 1 more check, the readings and the manual page (page 74). No card needed.See the full 9.1.17 answer

What it means

Parameter 7093 DHW Setpoint is outside its allowed range, so the controller flags a configuration fault. Manual chart 9.1.17 (page 74); code 126 on the controller fault list.

Likely causes

  1. Heat pump configuration error.
  2. Parameter 7093 DHW Setpoint set outside 40°C to 65°C.
  3. Faulty indoor unit RVS21.

Where to start

  1. Read the fault history to confirm the code and when it occurred: Settings, user level Installer (password), Test function menu, Fault History (6800 History 1, 6801 Fault Code 1), page
  2. The last 10 faults can be scrolled through.
  3. Re-configure the heat pump (Installer level, spanner menu, Quick Set Up, page 58) and check if the fault persists.

The full answer, free

  • 1 more check in order
  • The readings and component tests from the manual
  • How to put it right, step by step
  • The manual page for this fault (page 74), right under the answer

Safety: Isolate the heat pump and any backup heater, and give any inverter capacitors time to discharge before you open the electrics. Anything on the refrigerant circuit needs F-gas certification.

Full 9.1.17 fix, readings and manual page. Free.See the full answer

From the Ideal manual for the Logic Air. Check the model on the data plate before you order parts.